Air Compressor Runs Slow Then Trips Breaker

Jody

Updated on:

Air Compressor Runs Slow Then Trips Breaker

An air compressor running slow and tripping the breaker is often caused by an aging compressor that has trouble starting and pulls more electricity, causing the breaker to trip. A solution is to have an AC technician install a “hard start kit,” which is a capacitor that gives the compressor motor an extra electrical jolt to get it moving.

Circuit breakers can also trip due to current surges when a motor starts, shorts, ground faults, rusty connections, or extension cords. Additionally, low refrigerant charge can cause the compressor to overheat and trip the thermal overload protection device. Another potential issue is a weak or defective capacitor, which can trigger a tripped breaker if the compressor doesn’t receive adequate starting power.

Air Compressor Runs Slow Then Trips Breaker

Credit: www.amazon.com

Common Causes Of Slow Running And Tripping Breaker

When your air compressor is running slow and tripping the breaker, there are a few common causes that you should consider. By understanding these causes, you can diagnose the issue and take appropriate action, ensuring your air compressor runs smoothly and efficiently. The following are some of the most common causes of slow running and tripping breaker.

Excessive Current Draw

One potential cause for a slow running air compressor that trips the breaker is excessive current draw. If the compressor motor draws more current than the breaker’s capacity, it can overload the circuit and cause the breaker to trip. This can happen when the compressor ages and has trouble starting, pulling even more electricity. To resolve this issue, you can have an AC technician install a “hard start kit.” This kit includes a capacitor that provides the compressor motor with an extra electric jolt to get it moving.

Low Refrigerant Charge

Another possibility for slow running and tripping breaker is a low refrigerant charge. If the refrigerant charge is too low, it can cause the compressor to overheat and trip the thermal overload protection device. This can result in the air compressor running slowly or not running at all. To rectify this issue, you should check the refrigerant levels and ensure they are at the appropriate level. If the charge is low, you may need to add refrigerant to the system. It is important to consult with an HVAC professional to properly diagnose and address the issue.

Understanding The Relationship Between Current Draw And Breaker Tripping

How A Circuit Breaker Works

A circuit breaker is an important safety device that protects electrical circuits from overloading and causing damage. It acts as a safeguard by automatically shutting off the power supply when the current exceeds its rated capacity. When the circuit breaker trips, it interrupts the flow of electricity, preventing any potential hazards like electrical fires or damage to electrical equipment.

Motor Starting Current Surge

One of the common reasons behind an air compressor running slow and tripping the breaker is the excessive current draw during motor starting. When the compressor motor starts, it requires a high amount of electrical current to get it moving. This abrupt surge of current can exceed the capacity of the circuit breaker, causing it to trip. It is important to note that this starting current surge is temporary and should stabilize once the motor is up to speed.

Overload Protection Device

Another factor that can cause an air compressor to trip the breaker is an overload on the motor. If the compressor motor draws excessive current due to various reasons such as worn-out components or low refrigerant charge, it can trigger the overload protection device. This device is designed to detect when the current exceeds a safe limit and automatically turns off the compressor to prevent any damage or overheating.

If you are experiencing an air compressor that runs slow and trips the breaker, it is crucial to identify the root cause of the issue. It could be a faulty capacitor, low refrigerant charge, or an overloaded motor. Consulting with an HVAC technician is recommended to diagnose and resolve the problem effectively. They can assess the compressor’s condition, install a hard start kit if necessary to provide an extra electrical boost during startup, or replace any defective components as needed.

 

Solutions For Slow Running And Tripping Breaker

Installing A Hard Start Kit

If your air compressor is running slowly and tripping the breaker, one possible solution is to install a hard start kit. This kit includes a capacitor that provides an extra electrical “jolt” to the compressor motor, helping it start more efficiently. By giving the compressor motor the extra boost it needs, the hard start kit can prevent slow running and reduce the chances of the breaker tripping. To install the hard start kit, it is recommended to seek the assistance of an AC technician who can ensure proper installation and compatibility with your specific compressor model.

Checking And Replacing Run Capacitor

Another potential solution for a slow running air compressor that trips the breaker is to check and replace the run capacitor. The capacitor is responsible for providing the necessary electrical energy to start the compressor motor and keep it running smoothly. Over time, capacitors can weaken or fail, leading to slow running and breaker tripping. To determine if the run capacitor is the issue, visually inspect it for any signs of damage or bulging. If there are visible signs of damage or if the capacitor fails a capacitance test, it is recommended to replace it. Again, it is advisable to consult an AC technician for proper diagnosis and replacement of the run capacitor.

Addressing Low Refrigerant Charge

Low refrigerant charge can also contribute to a slow running air compressor that trips the breaker. When the refrigerant charge is too low, it causes the compressor to work harder and overheat, resulting in slow performance and breaker trips. To address this issue, it is crucial to have a professional HVAC technician assess and recharge the refrigerant to the correct levels. They will also inspect the system for any leaks that may be causing the refrigerant to escape, leading to the low charge. By addressing the low refrigerant charge, the compressor can operate at optimal levels, reducing the risk of slow running and breaker tripping.

In conclusion, if your air compressor is running slow and tripping the breaker, it is essential to explore these potential solutions. Installing a hard start kit, checking and replacing the run capacitor, and addressing low refrigerant charge can all help resolve these issues and ensure your air compressor operates efficiently and safely. Remember to consult with a qualified AC technician for proper diagnosis and implementation of these solutions.

Troubleshooting Ac Motor That Trips The Circuit Breaker

When your air compressor runs slow and then trips the circuit breaker, it can be frustrating and inconvenient. However, understanding the common causes of this issue and troubleshooting the AC motor can help you find a solution quickly. In this section, we will discuss how to test the motor, check for shorts, ground faults, and rusty connections to identify the underlying problem.

Testing The Motor

One of the first steps in troubleshooting an AC motor that trips the circuit breaker is to test the motor itself. Here’s a step-by-step guide on how to do it:

  1. Disconnect the motor from the power source and ensure that it is isolated.
  2. Using a multimeter, check the resistance between the motor’s terminals. A reading close to zero or infinite resistance indicates a faulty motor.
  3. Inspect the motor’s wiring for any loose or damaged connections. Tighten or replace them as necessary.
  4. Verify that the motor’s windings are not shorted. Continuity between the windings and ground indicates a short.
  5. If the motor passes all the tests, it is likely not the cause of the breaker tripping.

Checking For Shorts, Ground Faults, And Rusty Connections

In addition to testing the motor, it is important to check for shorts, ground faults, and rusty connections. Here are the steps to follow:

  1. Inspect the wiring and electrical connections for any signs of damage, such as frayed wires or exposed conductors.
  2. Check for any rust or corrosion on the electrical terminals and connections. Clean them thoroughly if necessary.
  3. Use a multimeter to test for continuity between the motor’s wiring and ground. A reading other than infinite resistance indicates a ground fault.
  4. If you suspect a short circuit, carefully inspect the wiring for any bare spots or damaged insulation.
  5. Repair or replace any faulty components or connections that may be causing the circuit breaker to trip.

By following these troubleshooting steps, you can identify the source of the problem and determine the appropriate solution. Whether it’s a faulty motor, a short circuit, or rusty connections, addressing these issues promptly can help your air compressor function properly without tripping the breaker.

Prevention And Maintenance Tips

Proper maintenance and regular inspections play a crucial role in keeping your air compressor in optimal condition. By following these prevention and maintenance tips, you can avoid issues like slow running and breaker trips, ensuring your air compressor operates smoothly and efficiently.

Regular Maintenance And Inspection

To prevent your air compressor from running slowly and tripping the breaker, it’s essential to perform regular maintenance and inspections. This allows you to identify any potential issues before they become major problems.

During your maintenance routine, make sure to clean the air compressor regularly. Remove dirt, dust, and debris from the air intake vents using a soft brush or cloth. This helps maintain proper airflow and prevents overheating.

Following Manufacturer Guidelines

Following the manufacturer’s guidelines is crucial for proper maintenance of your air compressor. Check the user manual or consult the manufacturer’s website for specific maintenance instructions, such as oil changes, filter replacement, and lubrication.

Keep a log of maintenance activities, including dates and tasks performed. This record will help you stay organized and ensure you never miss an important maintenance task.

Professional Assistance

In addition to regular maintenance, it may be necessary to seek professional assistance for more complex issues. If you notice persistent slow running or frequent breaker trips, contacting a qualified technician is recommended.

A professional technician will have the knowledge and expertise to diagnose and resolve any underlying issues with your air compressor. They can also conduct thorough inspections to identify potential problems that you may have missed.

Remember, a timely intervention by a professional can save you from costly repairs and prolong the lifespan of your air compressor.

In conclusion, prevention and maintenance are key to avoiding air compressor issues, such as slow running and breaker trips. By implementing regular maintenance and inspections, following manufacturer guidelines, and seeking professional assistance when necessary, you can ensure efficient and trouble-free operation of your air compressor.

Frequently Asked Questions Of Air Compressor Runs Slow Then Trips Breaker

Why Does My Compressor Keep Tripping The Breaker?

As your compressor ages, it may have trouble starting, pulling more electricity and causing the breaker to trip. An AC technician can install a “hard start kit,” which is a capacitor that gives the compressor motor an extra electrical boost to help it start.

Why Does My Motor Run For A Few Seconds Then Trips The Breaker?

A motor can run for a few seconds and then trip the breaker due to a current surge when starting, which exceeds the breaker’s capacity. Other possible causes include shorts, ground faults, rusty connections, and extension cords. Installing a “hard start kit” with an extra capacitor can help provide additional electrical power to the motor and prevent tripping.

What Does It Mean When A Compressor Is Tripping?

When a compressor is tripping, it usually means that either the compressor motor is drawing excessive current or the refrigerant charge is too low. This can cause the overload protection device to trip or the compressor to overheat. It can also be caused by issues such as shorts, ground faults, rusty connections, or extension cords.

To fix this issue, you can have an AC technician install a “hard start kit” or check for any damaged components like the condenser motor.

Will A Bad Run Capacitor Trip A Breaker?

A bad run capacitor can trip a breaker if the compressor doesn’t receive enough starting power. It’s important to have a professional HVAC contractor diagnose and replace a failing capacitor.

Conclusion

When your air compressor runs slow and trips the breaker, it can be frustrating and inconvenient. However, there are solutions to this common problem. Aging compressors may have trouble starting, causing excessive electricity draw and tripping the breaker. Installing a “hard start kit” can provide the extra electrical boost needed to get the motor running smoothly.

Additionally, circuit overloads, shorts, and low refrigerant charge can also cause breakers to trip. By addressing these issues, you can ensure that your air compressor operates efficiently and without interruptions.